<LOGO>
FM Transmitter Measurement Report
Created: 2026-10-27 01-15-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.40 MHz 5/5, 34 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
11 kHz 15 kHz 9674 0,0207
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,1 dBr -0,57 dBr 0,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 1:15, 27.10.2026
RT
"Analyzy a komentare - deni z domova i ze sveta "
AF EON
91.3, 92.6, 93.3, 93.5, 95.7, 97.9, 98.0, 98.2, 99.5, 101.9, 103.6 MHz -
FM Scope Max at: 15 kHz MIN: 11 kHz % above 77 kHz: 0,0207 Acquired: 2026/10/27 1:15:47 Total samples: 9674 Equivalent time: 0:08:03 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 0,2 dBr MIN: -1,1 dBr AVE: -0,57 dBr % above 0,2 dBr: 0,0 Last value: -0,7 dBr (2026/10/27 1:15:47) 01:02 01:04 01:06 01:08 01:10 01:12 01:14 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality